DR-15
DR series
- Product Overview
- Send Inquiry
-
1.Features
Universal AC input/ full range Protections: Short circuit/ Over load/ Over voltage Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 Isolation classⅡ No load power consumption<0.5W LED indicator for power on 100% full load burn-in test 2 years warranty 2. Specification
ModelDR-15-5DR15-12DR-15-15DR-15-24OUTPUTDC Voltage5V12V15V24VRated Current2.4A1.25A1A0.63ACurrent Range0-2.4A0-1.25A0-1A0-0.63ARated Power12W15W15W15.2WRipple & Noise80mVp-p120mVp-p120mVp-p150mVp-pVoltage Adj. Range-5%,+10%±10%±10%±10%Voltage Tolerance±2%±1%±1%±1%LINE REGULATION±1%±1%±1%±1%LOAD REGULATION±1%±1%±1%±1%Setup, Rise, Hold Up Time1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load 70ms/230VACHOLD UP TIME (Typ.)16ms/115VAC at full loadINPUTVoltage Range85 ~ 264VAC 120 ~ 370VDCFREQUENCY RANGE47 ~ 63HzAC Current0.88A/115VAC 0.48A/230VACEfficiency77%84%83.50%85%Inrush CurrentCOLD START 35A/115VAC 65A/230VACPROTECTIONOver Load105%~160% rated output powerProtection type: Constant current limiting, recovers automatically after fault condition is removedOver Voltage5.75 ~ 6.75V13.8 ~ 16.2V17.25 ~ 20.25V27.6 ~ 32.4VProtection type : Shut off o/p voltage, clamping by zener diodeENVIRONMENTWorking Temp.-20℃~+60℃(Refer to "Derating Curve")WORKING HUMIDITY20 ~ 90% RH non-condensingStorage Temp., Humidity-40 ~ +85 , 10 ~ 95% RHTemp. Coefficient±0.03%/℃(0~50℃)Vibration10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axesSAFETY &
EMCWithstand VoltageI/P-O/P: 3KVACIsolation ResistanceI/P-O/P:100M Ohms / 500VDC / 25 / 70% RHEMC EMISSIONCompliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3EMC IMMUNITYCompliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria AOTHERSMTBF1172.3K hrs min. MIL-HDBK-217F (25 ℃)DIMENSION25*93*56mm (W*H*D)3. Mechanical Dimension
4.Block Diagram
5.Derating Curve
6.Output Derating VS Input Voltage
7.Please Note1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. Constant current operation region is within 60% ~100% rated output voltage. Protection type for short circuit is hiccup mode and will recover automatically after fault condition is removed.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.