1.Features
1. Low price and high reliable. 2. 105 `C output capacitor 3. AC input power suitable for the world 4. High efficiency and how operation temperature. 5. Soft-start current can reduce the AC input impact effecticly. 6. With short-circuit and overload,over-volt protection. 7. Compact size, light weight. 8. 100% full-load buming test. 9. LED indicator for power on 2. Specification
Model
SpecificationD-100 AD-100 BDC Output Voltage5V12V5V24VIutput Voltage Error± 2%± 6%± 2%± 7%Rated Output Current15A2A15A1AOutput Current Range1-15A0.3-2A1-15A0.2-1ATripple and Noise100mVp-p100mVp-p100mVp-p100mVp-pIniet Stability± 0.5%± 1%± 0.5%± 1%Tolerance Voltage± 0.5%± 5%± 0.5%6%DC Output Power98W99WEfficiency78%80%Adjustable Range for DC Voltage`+10, -5%± 10, -5%AC Input Voltage Range85~132VAC/170~264VAC selected by switch 47~63Hz; 248~370VDCInput Current2.8A/115V 1.6A/230VAC Inrush CurrentCold-Start Current: 35A/115V, 35A/230VLeakage Current<3.5mA/240VACOverload Protection105 ~ 135% rated output power. Protection type : Shut down o/p voltage, re-power on to recover.Over Voltage ProtectionCH1:5.75 ~ 6.75VDC,Protection type : Shut down o/p voltage, re-power on to recover.High Temperature Protection…………Temperature Coefficient± 0.03% /℃ (0~50℃) on +5V outputStart, Rise, Hold time200ms, 50ms, 30msVibration10~500Hz, 2G 10min,/1cycle, a total of 60 minutes, Each axesWithstand VoltageBetween Input and Output: 3KVAC, Input and Shell: 1.5KVAC, Output and Shell: 0.5KVACIsolation ResistanceInput and Output Intermal: Input and Enclosute, Output and Enclosure: 500VDC/100M OhmsWorking Temperature and Humidity`-10℃~+60℃ (Refer to Output Derating Cutve), 20%~90%RHStorage Temperature and Humidity`20℃~+85℃, 10%~95%RHOverall Dimension199*110*50 mmWeight0.76 kgsSafety StandardsCEEMC StandardsMeet FCC Part 15J Conduction class B3. Mechanical Dimension
4.Please Note
1. The testing condition for the parameter above is: 230VAC input, rated load, 25℃ 70%Rh, Humidity. 2. Error, include the setting error, line stability and load stability. 3. Wave test: adopting "A12" double wire for 20MHZ, and 0.1uF&uF capacitor short-circuit for interrupting. 4. Inlet Voltage Stability test: when is over load, the lowest voltage of inler is representative to the highest voltage. 5. Load stability test: the load is from 0% to 100%, others 60%. 6. Total output canbe maximum Current, total load can not exceed the maximum output power. 7. C3,4,11 must be knocked down.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
- 上一篇:D-120B
- 下一篇:没有了