NES-35
NES series
- Product Overview
- Send Inquiry
-
1.Features
‧Universal AC input / Full range ‧Protections: Short circuit / Overload / Over voltage ‧Cooling by free air convection ‧100% full load burn-in test ‧2 years warranty 2. Specification
MODELNES-35-5NES-35-12NES-35-15NES-35-24NES-35-48OUTPUTDC VOLTAGE5V12V15V24V48VRATED CURRENT7A3A2.4A1.5A0.8ACURRENT RANGE0 ~ 7A0 ~ 3A0 ~ 2.4A0 ~ 1.5A0 ~ 0.8ARATED POWER35W36W36W36W38.4WRIPPLE & NOISE (max.) Note.280mVp-p120mVp-p150mVp-p200mVp-p240mVp-pVOLTAGE ADJ. RANGE4.75 ~ 5.5V10.8 ~ 13.2V13.5 ~ 16.5V21.6 ~ 26.4V43.2 ~ 52.8VVOLTAGE TOLERANCE Note.3±2.0%±1.0%±1.0%±1.0%±1.0%LINE REGULATION Note.4±0.5%±0.5%±0.5%±0.5%±0.5%LOAD REGULATION Note.5±0.5%±0.5%±0.5%±0.5%±0.5%SETUP, RISE TIME500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full loadHOLD UP TIME (Typ.)50ms/230VAC 10ms/115VAC at full loadINPUTVOLTAGE RANGE Note 785 ~ 264VAC 120 ~ 370VDCFREQUENCY RANGE47 ~ 63HzEFFICIENCY (Typ.)78%81%83%85%86%AC CURRENT (Typ.)0.75A/115VAC 0.5 A/230VACINRUSH CURRENT (Typ.)COLD START 45ALEAKAGE CURRENT<2mA / 240VACPROTECTIONOVERLOAD110 ~ 150% rated output powerProtection type : Hiccup mode, recovers automatically after fault condition is removedOVER VOLTAGE5.75 ~ 6.75V13.8 ~ 16.2V17.25 ~ 20.25V27.6 ~ 32.4V55.2 ~ 64.8VProtection type : Shut down o/p voltage, re-power on to recoverENVIRONMENTWORKING TEMP.-20 ~ +60℃(Refer to Derating Curve") "WORKING HUMIDITY20 ~ 90% RH non-condensingSTORAGE TEMP., HUMIDITY-40 ~ +85℃, 10 ~ 95% RHTEMP. COEFFICIENT± 0.03%℃/ (0 ~ 45 ℃ )VIBRATION10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axesSAFETY & EMC Note 8WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVACISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RHEMC EMISSIONCompliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria AOTHERSMTBF394Khrs min. MIL-HDBK-217F (25℃)DIMENSION99*97*36mm (L*W*H)3. Mechanical Dimension
4. Block Diagram
5.Derating Curve
6.Output Derating VS Input Voltage
7. Please Note
1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be rre-confirmed that it still meets EMC directives. For guidance on how to perform these EMS test, please refer to "EMI testing of component power suppliers."
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.