NES-100
NES series
- Product Overview
- Send Inquiry
-
1.Features
‧Protections: Short circuit / Overload / Over voltage ‧Cooling by free air convection ‧LED indicator for power on ‧100% full load burn-in test ‧2 years warranty 2. Specification
MODELNES-100-5NES-100-7.5NES-100-9NES-100-12NES-100-15NES-100-24NES-100-48OUTPUTDC VOLTAGE5V7.5V9V12V15V24V48VRATED CURRENT20A13.6A11.2A8.5A7A4.5A2.3ACURRENT RANGE0 ~ 20A0 ~ 13.6A0 ~ 11.2A0 ~ 8.5A0 ~ 7A0 ~ 4.5A0 ~ 2.3ARATED POWER100W102W100.8W102W105W108W110.4WRIPPLE & NOISE (max.) Note.280mVp-p120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p150mVp-pVOLTAGE ADJ. RANGE4.75 ~ 5.5V7.13 ~ 8.3V8.55 ~ 9.9V11.4 ~ 13.2V14.25 ~ 16.5V22.8 ~ 26.4V45.6 ~ 52.8VVOLTAGE TOLERANCE Note.3±2.0%±1.0%±1.0%±1.0%±1.0%±1.0%±1.0%LINE REGULATION Note.4±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%LOAD REGULATION Note.5±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%±0.5%SETUP, RISE TIME1000ms, 20ms/230VAC 1000ms, 20ms/115VAC at full loadHOLD UP TIME (Typ.)30ms/230VAC 25ms/115VAC at full loadINPUTVOLTAGE RANGE Note 785 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDCFREQUENCY RANGE47 ~ 63HzEFFICIENCY (Typ.)80%81%81%83%84%86%86%AC CURRENT (Typ.)2A/115VAC 1.2A/230VACINRUSH CURRENT (Typ.)COLD START 45ALEAKAGE CURRENT<2mA / 240VACPROTECTIONOVERLOAD110 ~ 150% rated output powerProtection type : Hiccup mode, recovers automatically after fault condition is removedOVER VOLTAGE5.75 ~ 6.75V8.6 ~ 10.1V10.4 ~ 12.2V13.8 ~ 16.2V17.25 ~ 20.25V27.6 ~ 32.4V55.2 ~ 64.8VProtection type : Hiccup mode, recovers automatically after fault condition is removedENVIRONMENTWORKING TEMP.-20 ~ +60℃(Refer to Derating Curve") "WORKING HUMIDITY20 ~ 90% RH non-condensingSTORAGE TEMP., HUMIDITY-40 ~ +85℃, 10 ~ 95% RHTEMP. COEFFICIENT± 0.03%℃/ (0 ~ 50 ℃ )VIBRATION10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axesSAFETY & EMC Note 8WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVACISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RHEMC EMISSIONCompliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria AOTHERSMTBF320.7Khrs min. MIL-HDBK-217F (25℃)DIMENSION159*97*38mm (L*W*H)3. Mechanical Dimension
4. Block Diagram
5.Derating Curve
6.Output Derating VS Input Voltage
7. Please Note
1. All parameters not specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. When using DC voltage as the input, please connect positive pole of input voltage to mark “N” of the terminal block and negative pole of input voltage to mark “L” of the terminal block.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.