SP-75
SP series
- Product Overview
- Send Inquiry
-
1.Features :
1. Universal AC input / Full range 2. Built-in active PFC function, PF>0.93 3. Protections: Short circuit / Overload / Over voltage / Over temperature 4. Built-in constant current limiting circuit 5. Remote ON-OFF control(Optional) 6. LED indicator for power on 7. 100% full load burn-in test 8. Fixed switching frequency at PFC:67KHz PWM:134KHz 9. 2 years warranty 2. Specification
Model/Spec.SP-75-3.3SP-75-5SP-75-7.5SP-75-12SP-75-13.5SP-75-15SP-75-24SP-75-27SP-75-48DC Output Voltage3.3V5V7.5V12V13.5V15V24V27V48VIutput Voltage Error± 2%± 2%± 2%± 2%± 2%± 2%± 1%± 1%± 1%Rated Output Current15A15A10A6.3A5.6A5A3.2A2.8A1.6AOutput Current Range0-15A0-15A0-10A0-6.3A0-5.6A0-5A0-3.2A0-2.8A0-1.6ATripple and Noise80mVp-p80mVp-p80mVp-p80mVp-p80mVp-p80mVp-p100mVp-p100mVp-p100mVp-pIniet Stability± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%Tolerance Voltage± 1%± 1%± 1%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%DC Output Power49.5 W75W75W75.6W75.6W75W76.8W75.6W76.8WEfficiency70%76%79%81%82%82%83%83%83%Adjustable Range for DC Voltage3.14 ~ 3.63V4.75 ~ 5.5V7.13 ~ 8.25V11.4 ~ 13.2V12.8 ~ 14.9V14.3 ~ 16.5V22.8 ~ 26.4V25.7 ~ 29.7V45.6 ~ 52.8VAC Input Voltage Range85 ~ 264VAC 120 ~ 370VDC 47-63HZPower factorPF>0.93/230VAC PF>0.98/115VAC at full loadInput Current1.3A/115V 0.7A/230VAC Inrush CurrentCold-Start Current: 45A/230VLeakage Current<2mA/240VACOverload Protection105%~150% rated output power ,Protection type : Constant current limiting, recovers automatically after fault condition is removedOver Voltage Protection3.8-4.46V5.75-6.75V8.63-10.13V13.8-16.2V15.53-18.2V17.25-20.25V27.6-32.4V31.05-36.45V55.2-64.8VProtection type : Shut down o/p voltage, re-power on to recoverREMOTE CONTROL(OPTION)CN1:4 ~ 10VDC POWER ON, <0 ~ 0.8VDC POWER OFFTemperature Coefficient±0.05%/℃ (0 ~ 50℃)Start, Rise, Hold time800ms, 60ms at full load ,hold time:36ms at full loadVibration10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axesWithstand VoltageI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVACIsolation ResistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RHWorking Temperature and Humidity.-10~+60℃ (Refer to output and "Derating Curve"), 20 ~ 90% RH non-condensingStorage Temperature and Humidity`-20℃~+85℃, 10%~95%RHOverall Dimension179*97*33mmMTBF208.8k hrs min.Safety StandardsCEEMC StandardsCompliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A3. Mechanical Dimension:
4.Block Diagram
5.Derating Curve
6.Output Derating VS Input Voltage
7.Please Note:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
- 上一篇:没有了
- 下一篇:SP-100