SCN-1500
SCN series
- Product Overview
- Send Inquiry
-
1.Features :
1. AC input 200~240V only 2. Protections: Short circuit / Overload / Over voltage / Over temp. 3. High reliability/ Low ripple noise 4. Built-in remote sense function 5. Built-in remote ON-OFF control 6. Built-in parallel operation function 7. Can adjust from 20~100% output voltage by external control 1-5V 8. Forced air cooling by built-in DC fan 9. Case coating with paint 10. 2 years warranty 2. Specification
Model
SpecificationSCN-1K5-12SCN-1K5-15SCN-1K5-24SCN-1K5-48DC Output Voltage12V15V24V48VIutput Voltage Error± 1%± 1%± 1%± 1%Rated Output Current125A100A62.5A32AOutput Current Range0-125A0-100A0-62.5A0-32ATripple and Noise240mVp-p240mVp-p240mVp-p480mVp-pVoltage Adj range±5.0% typical adjustment by potentiometer 20~100% adjustment by 1~5VDC external controlIniet Stability± 0.5%± 0.5%± 0.5%± 0.5%Tolerance Voltage± 1%± 1%± 1%± 1%DC Output Power1500W1500W1500W1536WEfficiency84%83%85.5%87%AC Input Voltage Range200 ~ 240VAC 290 ~ 370VDCInput Current15.0A/230VACAC Inrush CurrentCold-Start Current: 120A / 230VACLeakage Current3.5mA/240VACOverload Protection110 ~ 135% rated output power,Current limiting, delay shut down o/p voltage, re-power on to recoverOver Voltage Protection110 ~ 135% follow to output set up point, Shut down o/p voltage, re-power on to recoverHigh Temperature Protection>100℃ / measure by heat sink, near transformer,Shut down o/p voltage, re-power on to recoverTemperature Coefficient± 0.04% /℃ (0~50℃)Start, Rise, Hold time800ms, 50ms, 16ms at full loadVibration10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axesWithstand VoltageI/P-O/P, I/P-FG:1500VACIsolation ResistanceI/P-O/P, I/P-FG, 100M Ohms / 500VDC / 25 ℃/ 70% RHWorking Temp,Humidity`-10℃~+60℃ (Refer to Output Derating Cutve), 20%~90%RHStorage Temp,Humidity`20℃~+85℃, 10%~95%RHMTBF60Khrs min. MIL-HDBK-217F (25 ℃)Overall Dimension291*132*132 mmWeight4.75 kgsSpecial functionDC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)Safety StandardsCEEMC StandardsMeet FCC Part 15J Conduction class A3. Mechanical Dimension:
4.Derating Curve
5.External DC Control VS Output Voltage
6. Please Note:
1. 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. Tolerence: includes set up tolerance, line regulation, load regulation 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.