SCN-800
SCN series
- Product Overview
- Send Inquiry
-
1.Features : 1. AC input range selected by switch 2. Protections: Short circuit / Overload / Over voltage / Over temp. 3. High reliability/ Low ripple noise 4. Built-in remote sense function 5. Built-in remote ON-OFF control 6. Built-in parallel operation function 7. Can adjust from 20~100% output voltage by external control 1-5V 8. Forced air cooling by built-in DC fan 9. Case coating with paint 10. 2 years warranty 2. Specification
Model
SpecificationSCN-800-12SCN-800-13.5SCN-800-15SCN-800-24SCN-800-27SCN-800-48DC Output Voltage12V13.5V15V24V27V48VIutput Voltage Error± 1%± 1%± 1%± 1%± 1%± 1%Rated Output Current66A59A53A33A30A16AOutput Current Range0-66A0-59A0-53A0-33A0-30A0-16ATripple and Noise360mVp-p360mVp-p360mVp-p300mVp-p300mVp-p300mVp-pVoltage Adj range±5.0% typical adjustment by potentiometer 20~100% adjustment by 1~5VDC external controlIniet Stability± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%Tolerance Voltage± 1%± 1%± 1%± 1%± 1%± 1%DC Output Power792W796.5W795W792W810W768WEfficiency84%84%83%85.5%86.5%87%AC Input Voltage Range90 ~ 130VAC / 180 ~ 260VAC selected by switch, 260 ~ 370VDCInput Current13A/115VAC 8.0A/230VACAC Inrush CurrentCold-Start Current: 60A / 230VACLeakage Current3.5mA/240VACOverload Protection110 ~ 135% rated output power,Current limiting, delay shut down o/p voltage, re-power on to recoverOver Voltage Protection110 ~ 135% follow to output set up point, Shut down o/p voltage, re-power on to recoverHigh Temperature Protection>100℃ / measure by heat sink, near transformer,Shut down o/p voltage, re-power on to recoverTemperature Coefficient± 0.04% /℃ (0~50℃)Start, Rise, Hold time800ms, 50ms, 16ms at full loadVibration10 ~ 200Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axesWithstand VoltageI/P-O/P, I/P-FG:1500VACIsolation ResistanceI/P-O/P, I/P-FG, 100M Ohms / 500VDC / 25 ℃/ 70% RHWorking Temp,Humidity`-10℃~+60℃ (Refer to Output Derating Cutve), 20%~90%RHStorage Temp,Humidity`20℃~+85℃, 10%~95%RHMTBF120Khrs min. MIL-HDBK-217F (25℃ )Overall Dimension291*132*68 mmWeight2.65 kgsSpecial functionDC voltage adj., Remote sensing, remote control, parallel operation (refer to terminal instruction manual)Safety StandardsCEEMC StandardsMeet FCC Part 15J Conduction class A3. Mechanical Dimension
4.Derating Curve
5.External DC Control VS Output Voltage
6.Control terminal instruction manual
7.Please Note
1. 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient. 2. Tolerence: includes set up tolerance, line regulation, load regulation 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
- 上一篇:SCN-600
- 下一篇:没有了