S-500
S series
- Product Overview
- Send Inquiry
-
1.Features ·Protections: short circuit/over load/over voltage /over temp ·AC input voltage range selected by switch ·Small volume, low weight, high efficiency ·100% full load burn-in test ·2 Year warranty ·Built-in cooling DC fan ·Cooling fan ON-OFF auto control ·LED indicator for power on 2. Specification
Model SpecificationS-500-12S-500-15S-500-24S-500-48OUTPUTDC output voltage12V15V24V48VOutput voltage tolerance±1%±1%±1%±1%Rated output current41.5A33A20.8A10.5AOutput current range0~41.5A0-33A0-20.8A0-10.5ARipple & noise200mVp-p200mVp-p240mVp-p240mVp-pDC adjustable voltage range10-13.2V13.5-18V20-26.4V41-56VDC output power500W495W500W504WInlet stability±0.5%±0.5%±0.5%±0.5%Load stability±1%±0.5%±0.5%±0.5%Setup rise hold up time200ms,50ms,20msINPUTAC input voltage range90~132VAC/180~264VAC selected by switch, 248~370VDCFrequency range47~63Hz;Input current6.5A/115V 4A/230VAC impulse current25A/115V 50A/230VLeakage current<3.5mA/240VACEfficiency78%81%83%84%PROTECTIONOverload protection105%~135%. Type,PULSING HICCUP SHUTDOWN; Reset,auto recoveryOver-voltage protection13.8-16.2V18-21V27.6-32V57.6-67.2VHigh-temperature protectionRTH3>=65°C FAN ON<=55°C FAN OFF>=80°CCut off output(5~15V)RTH3>=70°C FAN ON<=60°C FAN OFF>=85°CCut off output(24~48V)ENVIRONMENTTemperature coefficient±0.03%°C(0~50°C)Vibration10~500Hz,2G 10min./1cycle,Period for 60min,EACH AXESIsolation resistanceInput & output interval,Input & enclosure,Output & enclosure,500VAC/100M OhmsWorking temp & humidity-10°C~+50°C,20~90%RHStore tempe & humidity-20°C~+85°C,10~95%RHSAFETY & EMC Note 8Withstand voltageInput & output interval,1.5KVAC.Input & enclosure,1.5KVAC. Output & enclosure,0.5KVACSafety standardsDesign refer to UL1012, EN60950-1,EN61347-1,EN-61347-2 approvedEMC standardsEN55015,EN55022,EN55024,EN61000-2,EN61000-3,EN61547 approvedOTHERSOverall dimension(L×W×H) 241*124*65 mmWeight1.4Kgs /10pcs per carton3. Mechanical Dimension
4.Please Note
1.The testing condition for the parameter above is,230VAC input, rated load,25°C 70%Rh,Humidity 2.Error,include the setting error, line stability and load stability.(Note,5) 3.Wave test,adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting 4.Inlet voltage stability test, when is over load, the lowest voltage of inlet is representative to the highest voltage. 5.Load stability test: The load is from 0% to 100%,others 60%. 6.C2,3,11must be knocked down
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.