T-100
Triple output series
- Product Overview
- Send Inquiry
-
1.Features 1. Low price and high reliable. 2. 105 `C output capacitor 3. AC input power suitable for the world 4. High efficiency and how operation temperature. 5. Soft-start current can reduce the AC input impact effecticly. 6. With short-circuit and overload protection. 7. Compact size, light weight. 8. 100% full-load buming test. 9. installed with EMI filter, minmum wave. 2. Specification
Model
SpecificationT-100 CT-100 DDC Output Voltage5V15V`-15V`5V12V`24VRated Output Current10A2.5A1A8A22AOutput Current Range2-12A0.5-2.5A0-1A2-10A1-2A0.2-2ATripple and Noise80mVp-p150mVp-p150mVp-p80mVp-p150mVp-p150mVp-pIniet Stability± 0.5%± 1%± 1%± 0.5%± 1%± 1%Tolerance Voltage± 1%± 10,`5%± 10,`5%± 2%± 6%± 6%DC Output Power117.5W118WEfficiency77%79%Adjustable Range for DC Voltage`+10, -5%± 10, -5%AC Input Voltage Range85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDCInput Current2.5A/115V 1.25A/230VAC Inrush CurrentCold-Start Current: 30A/115V, 60A/230VLeakage Current<1mA/240VACOverload Protection105%~150% Type: Foldback Current Limiting, Reset: Auto RecoveryOver Voltage Protection…………High Temperature Protection…………Temperature Coefficient± 0.03% /℃ (0~50℃)Start, Rise, Hold time800ms,50ms,16ms/ 115VAC; 300ms,50ms,80ms /230VACVibration10~500Hz, 2G 10min,/1cycle, a total of 60 minutes, Each axesWithstand VoltageI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVACIsolation ResistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/70%RHWorking Temperature and Humidity`-10℃~+60℃ (Refer to Output Derating Cutve), 20%~90%RHStorage Temperature and Humidity`20℃~+85℃, 10%~95%RHOverall Dimension199*110*50 mmWeight0.83 kgs3. Mechanical Dimension
4. Block Diagram
5. Please Note1. The testing condition for the parameter above is: 230VAC input, rated load, 25℃ 70%Rh, Humidity. 2. Error, include the setting error, line stability and load stability. 3. Wave test: adopting "A12" double wire for 20MHZ, and 0.1uF&uF capacitor short-circuit for interrupting. 4. Inlet Voltage Stability test: when is over load, the lowest voltage of inler is representative to the highest voltage. 5. Load stability test: the load is from 0% to 100%, others 60%. 6. Total output canbe maximum Current, total load can not exceed the maximum output power.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.