DR-30
DR series
- Product Overview
- Send Inquiry
-
1.Features
Universal AC input/ full range Protections: Short circuit/ Over load/ Over voltage Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 Isolation classⅡ LED indicator for power on 100% full load burn-in test 2 years warranty 2. Specification
ModelDR-30-5DR-30-12DR-30-15DR-30-24OUTPUTDC Voltage5V12V15V24VRated Current3A2A2A1.5ACurrent Range0-3A0-2A0-2A0-1.5ARated Power15W24W30W36WRipple & Noise (max.) Note.280mVp-p120mVp-p120mVp-p150mVp-pVoltage Adj. Range4.75 ~ 5.5V10.8 ~ 13.2V13.5 ~ 16.5V21.6 ~ 26.4VVoltage Tolerance Note.3±2%±1%±1%±1%LINE REGULATION±1%±1%±1%±1%LOAD REGULATION±1%±1%±1%±1%Setup, Rise Time100ms,30ms/230VAC 100ms,30ms/115VAC at full loadHold Up Time100ms/230VAC 21ms/115VAC at full loadINPUTVoltage Range85~264VAC 120~370VDCFREQUENCY RANGE47~63HzAC Current0.88A/115V 0.48A/230VEfficiency74%81%82%83%Inrush CurrentCold start 15A/115V 30A/230VPROTECTIONOver Load105%~160% rated output powerProtection type: Constant current limiting, recovers automatically after fault condition is removedOver Voltage5.75 ~ 6.75V13.8 ~ 16.2V17.25 ~ 20.25V27.6 ~ 32.4VProtection type: Shut down o/p voltage, re-power on to recoverENVIRONMENTWorking Temp.,-20°C~+60°C; (Refer to "Derating Curve")WORKING HUMIDITY20 ~ 90% RH non-condensingStorage Temp., Humidity-40°C~+85°C; 10%~95%RHTemp. Coefficient±0.03%/°C(0~50°C)Vibration10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axesSAFETYWithstand VoltageI/P-O/P: 3KVACIsolation ResistanceI/P-O/P: 100M Ohms / 500VDCEMC EMISSIONCompliance to EN55011, EN55022 (CISPR22) Class B, EN61000-3-2,-3EMC IMMUNITYCompliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria AOTHERSMTBF441.5K hrs min. MIL-HDBK-217F (25°C)DIMENSION78*93*56mm (W*H*D)3.Mechanical Specification
4.Block Diagram
5.Derating Curve
6.Output Derating VS Input Voltage
7. Please Note
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
- 上一篇:没有了
- 下一篇:DR-45