D-30
- Product Overview
- Send Inquiry
-
1. Features
1. Low price and high reliable.
2. 105 `C output capacitor
3. AC input power suitable for the world
4. High efficiency and how operation temperature.
5. Soft-start current can reduce the AC input impact effecticly.
6. With short-circuit and overload protection.
7. Compact size, light weight.
8. 100% full-load buming test.
9. installed with EMI filter, minmum wave.
10. D-50 Dual Output Switch Power Supply SMPS Adapter Dual Group PSU
2. Specification
Model
SpecificationD-30 AD-30 BDC Output Voltage5V12V5V24VIutput Voltage Error± 2%± 3, -7%± 2%± 3, -5%Rated Output Current4A1A2.2A1AOutput Current Range0.5-4A0.1-1A0.5-4A0.1-1ATripple and Noise50mVp-p100mVp-p50mVp-p100mVp-pIniet Stability± 0.5%± 1%± 0.5%± 1%Tolerance Voltage± 0.5%± 4%± 0.5%4%DC Output Power32W35WEfficiency72%74%Adjustable Range for DC Voltage`+10, -5%± 10, -5%AC Input Voltage Range85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDCInput Current0.8A/115V 0.45A/230VAC Inrush CurrentCold-Start Current: 18A/115V, 36A/230VLeakage Current<0.5mA/240VACOverload Protection105%~150% Type: Foldback Current Limiting, Reset: Auto RecoveryOver Voltage Protection…………High Temperature Protection…………Temperature Coefficient± 0.03% /°C (0~50°C)Start, Rise, Hold time200ms, 50ms, 30msVibration10~500Hz, 2G 10min,/1cycle, a total of 60 minutes, Each axesWithstand VoltageBetween Input and Output: 1.5KVAC, Input and Shell: 1.5KVAC, Output and Shell: 0.5KVACIsolation ResistanceInput and Output Intermal: Input and Enclosute, Output and Enclosure: 500VDC/100M OhmsWorking Temperature and Humidity`-10°C~+60°C (Refer to Output Derating Cutve), 20%~90%RHStorage Temperature and Humidity`20°C~+85°C, 10%~95%RHOverall Dimension129*98*38mmWeight0.4 kgsSafety StandardsCEEMC StandardsMeet FCC Part 15J Conduction class B3. Mechanical Dimension
4. Please Note
1. The testing condition for the parameter above is: 230VAC input, rated load, 25°C 70%Rh, Humidity.
2. Error, include the setting error, line stability and load stability.
3. Wave test: adopting "A12" double wire for 20MHZ, and 0.1uF&uF capacitor short-circuit for interrupting.
4. Inlet Voltage Stability test: when is over load, the lowest voltage of inler is representative to the highest voltage.
5. Load stability test: the load is from 0% to 100%, others 60%.
6. Total output canbe maximum Current, total load can not exceed the maximum output power.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.
- 上一篇:没有了