S-250
- Product Overview
- Send Inquiry
-
1.Features
1. Input voltage selected by switch
2. Protection: short-circuit/ over-load/ over-voltage protection
3. Cooling by air
4. 100% full load burn-in test
5. 1 year warranty
2. Specification
Model
SpecificationS-250-5VS-250-12VS-250-13.5VS-250-15VS-250-24VS-250-27VS-201-48VDC Output Voltage5V12V13.5V15V12V27V48VIutput Voltage Error± 2%± 2%± 1%± 1%± 1%± 1%± 1%Rated Output Current45A20A18.6A16.7A10A9A5AOutput Current Range0-45A0-20A0-18.6A0-16.7A0-10A0-9A0-5ATripple and Noise200mVp-p150mVp-p150mVp-p150mVp-p150mVp-p150mVp-p240mVp-pIniet Stability± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%Tolerance Voltage± 1%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%DC Output Power247.5W240W248W250.5W240W243W240WEfficiency75%79%79%80%81%82%84%Adjustable Range for DC Voltage6-9V10-13.2V12-15V13.5-18V20-26.4V26-32V41-56VAC Input Voltage Range88~132VAC/176~264VAC selected by switch 47~63Hz; 240~370VDCInput Current5A/115V 2.5A/230VAC Inrush CurrentCold-Start Current: 30A/115V, 60A/230VLeakage Current<3.5mA/240VACOverload Protection105%~150% Type: Cut Output, Reset: Auto RecoveryOver Voltage Protection…………High Temperature Protection…………Temperature Coefficient± 0.03% /℃ (0~50℃)Start, Rise, Hold time200ms, 100ms, 20msVibration10~500Hz, 2G 10min,/1cycle, a total of 60 minutes, Each axesWithstand VoltageBetween Input and Output: 1.5KVAC, Input and Shell: 1.5KVAC, Output and Shell: 0.5KVACIsolation ResistanceInput and Output Intermal: Input and Enclosute, Output and Enclosure: 500VDC/100M OhmsWorking Temperature and Humidity`-10℃~+60℃ (Refer to Output Derating Cutve), 20%~90%RHStorage Temperature and Humidity`20℃~+85℃, 10%~95%RHOverall Dimension215*115*50 mmWeight1.10 kgsSafety StandardsCEEMC StandardsMeet FCC Part 15J Conduction class B3. Mechanical Dimension
4.Please Note1. The testing condition for the parameter above is: 230VAC input, rated load, 25℃ 70%Rh, Humidity. 2. Error, include the setting error, line stability and load stability. 3. Wave test: adopting "A12" double wire for 20MHZ, and 0.1uF&uF capacitor short-circuit for interrupting. 4. Inlet Voltage Stability test: when is over load, the lowest voltage of inler is representative to the highest voltage. 5. Load stability test: the load is from 0% to 100%, others 60%. 6. C3.4 must be knocked down,
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.