S-150
- Product Overview
- Send Inquiry
-
1.Features
1. Input voltage selected by switch
2. Protection: short-circuit/ over-load/ over-voltage protection
3. Cooling by air
4. 100% full load burn-in test
5. 1 year warranty
2. Specification
Model
SpecificationS-150-5VS-150-7.5VS-150-9VS-150-12VS-150-13.5VS-150-15VS-150-24VS-150-27VS-150-48VDC Output Voltage5V7.5V9V12V13.5V15V24V27V48VIutput Voltage Error± 2%± 1%± 1%± 1%± 1%± 1%± 1%± 1%± 1%Rated Output Current30A20A16.7A12.5A11.2A10A6.5A5.6A3.2AOutput Current Range0-30A0-20A0-16.7A0-12.5A0-11.2A0-10A0-6.5A0-5.6A0-3.2ATripple and Noise150mVp-p150mVp-p180mVp-p180mVp-p180mVp-p180mVp-p240mVp-p240mVp-p240mVp-pIniet Stability± 0.5%± 0.5%± 0.3%± 0.3%± 0.3%± 0.3%± 0.2%± 0.2%± 0.2%Tolerance Voltage± 0.5%± 0.5%± 0.3%± 0.3%± 0.3%± 0.3%± 0.2%± 0.2%± 0.2%DC Output Power150W150W150.3W150W151.2W150W156W151.2W153.6WEfficiency78%80%80%82%83%84%85%86%87%Adjustable Range for DC Voltage4.5-5.5V6-8.3V8-10.4V10.6-13.2V12-15V13.5-16.5V21-28V24-30V43-53VAC Input Voltage Range85~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDCInput Current3.2A/115V 1.6A/230VAC Inrush CurrentCold-Start Current: 35A/115V, 60A/230VLeakage Current<3.5mA/240VACOverload Protection105%~150% Type: Cut Output, Reset: Auto RecoveryOver Voltage Protection…………High Temperature Protection…………Temperature Coefficient± 0.03% /℃ (0~50℃)Start, Rise, Hold time100ms, 50ms, 20msVibration10~500Hz, 2G 10min,/1cycle, a total of 60 minutes, Each axesWithstand VoltageBetween Input and Output: 1.5KVAC, Input and Shell: 1.5KVAC, Output and Shell: 0.5KVACIsolation ResistanceInput and Output Intermal: Input and Enclosute, Output and Enclosure: 500VDC/100M OhmsWorking Temperature and Humidity`-10℃~+60℃ (Refer to Output Derating Cutve), 20%~90%RHStorage Temperature and Humidity`20℃~+85℃, 10%~95%RHOverall Dimension199*110*50mmWeight0.8kgsSafety StandardsCEEMC StandardsMeet FCC Part 15J Conduction class B3. Mechanical Dimension
4.Please Note1. The testing condition for the parameter above is: 230VAC input, rated load, 25℃ 70%Rh, Humidity. 2. Error, include the setting error, line stability and load stability. 3. Wave test: adopting "A12" double wire for 20MHZ, and 0.1uF&uF capacitor short-circuit for interrupting. 4. Inlet Voltage Stability test: when is over load, the lowest voltage of inler is representative to the highest voltage. 5. Load stability test: the load is from 0% to 100%, others 60%. 6. C2,3,11 must be knocked down.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.