1.Features
1. Input voltage selected by switch
2. Protection: short-circuit/ over-load/ over-voltage protection
3. Cooling by air
4. 100% full load burn-in test
5. 1 year warranty
2. Specification
Model
SpecificationS-201-5VS-201-7.5VS-201-12VS-201-13.5VS-201-15VS-201-24VS-201-27VS-201-48VDC Output Voltage5V7.5V12V13.5V15V24V27V48VIutput Voltage Error± 2%± 2%± 1%± 1%± 1%± 1%± 1%± 1%Rated Output Current40A26.5A16.5A14.7A13A8.3A7.4A4.2AOutput Current Range0-40A0-26.5A0-16.5A0-14.7A0-13A0-8.3A0-7.4A0-4.2ATripple and Noise180mVp-p180mVp-p120mVp-p120mVp-p120mVp-p120mVp-p150mVp-p240mVp-pIniet Stability± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%Tolerance Voltage± 1%± 1%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%± 0.5%DC Output Power200W198.75W198W198.45W198W199.2W199.8W201.6WEfficiency75%75%79%79%80%81%82%84%Adjustable Range for DC Voltage4.5-5.6V6-9V10-13.2V12-15V13.5-18V20-26.4V26-32V41-56VAC Input Voltage Range90~132VAC/170~264VAC selected by switch 47~63Hz; 240~370VDCInput Current4.5A/115V 2.5A/230VAC Inrush CurrentCold-Start Current: 25A/115V, 50A/230VLeakage Current<3.5mA/240VACOverload Protection105%~150% Type: Cut Output, Reset: Auto RecoveryOver Voltage Protection…………High Temperature Protection…………Temperature Coefficient± 0.03% /℃ (0~50℃)Start, Rise, Hold time200ms, 100ms, 20msVibration10~500Hz, 2G 10min,/1cycle, a total of 60 minutes, Each axesWithstand VoltageBetween Input and Output: 1.5KVAC, Input and Shell: 1.5KVAC, Output and Shell: 0.5KVACIsolation ResistanceInput and Output Intermal: Input and Enclosute, Output and Enclosure: 500VDC/100M OhmsWorking Temperature and Humidity`-10℃~+60℃ (Refer to Output Derating Cutve), 20%~90%RHStorage Temperature and Humidity`20℃~+85℃, 10%~95%RHOverall Dimension215*115*50 mmWeight1.3 kgsSafety StandardsCEEMC StandardsMeet FCC Part 15J Conduction class B3. Mechanical Dimension
4.Please Note1. The testing condition for the parameter above is: 230VAC input, rated load, 25℃ 70%Rh, Humidity. 2. Error, include the setting error, line stability and load stability. 3. Wave test: adopting "A12" double wire for 20MHZ, and 0.1uF&uF capacitor short-circuit for interrupting. 4. Inlet Voltage Stability test: when is over load, the lowest voltage of inler is representative to the highest voltage. 5. Load stability test: the load is from 0% to 100%, others 60%. 6. C3.4 must be knocked down,
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.