DRT-240
DR series
- Product Overview
- Send Inquiry
-
1.Features
Three-Phase AC 340 ~ 550V wide range input High efficiency 89% and low dissipation Protections: Short circuit/Over load/Over voltage/Over temperature Cooling by free air convection Built-in constant current limiting circuit Can be installed on DIN rail TS-35/7.5 or 15 100% full load burn-in test Fixed switching frequency at 70KHz 2 years warranty 2.SPECIFICATION
ModelDRT-240-24DRT-240-48OUTPUTDC Voltage24V48VRated Current10A5ACurrent Range0 ~ 10A0 ~5ARated Power240W240WRipple & Noise (max.) Note.280mVp-p80mVp-pVoltage Adj. Range24 ~ 28V48 ~ 55VVoltage Tolerance Note.3±1%±1%LINE REGULATION±0.5%±0.5%LOAD REGULATION±0.5%±0.5%Setup, Rise Hold Up Time1200ms, 40ms, 20ms/400VAC 800ms, 40ms, 40ms/500VAC at full loadINPUTVoltage Range Note.5Three-Phase 340 ~ 550VAC (Dual phase operation possible) 480 ~ 780VDCFREQUENCY RANGE47~63HzAC Current0.95A/400VAC 0.75A/500VACEfficiency89%Inrush Current
COLD START 50ALEAKAGE CURRENT<3.5mA /530VACPROTECTIONOver Load105%~150% rated output powerProtection type: Constant current limiting, recovers automatically after fault condition is removedOver Voltage30 ~ 36V59 ~ 66VProtection type : Shut down o/p voltage, re-power on to recoverOVER TEMPERATURE100°C±5°C(TSW1) detect on heatsink of power switchProtection type : Shut down o/p voltage, recovers automatically after temperature goes downENVIRONMENTWorking Temp.,-20°C~+70°C; (Refer to "Derating Curve")WORKING HUMIDITY20 ~ 90% RH non-condensingStorage Temp., Humidity-40°C~+85°C; 10%~95%RHTemp. Coefficient±0.03%/°C(0~50°C)Vibration10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axesSAFETYWithstand VoltageI/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVACIsolation ResistanceI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RHEMC EMISSIONCompliance to EN55011, EN55022 (CISPR22) Class B, EN61000-3-2,-3EMC IMMUNITYCompliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria AOTHERSMTBF114.6K hrs min. MIL-HDBK-217F (25°C )DIMENSION125.5*125.2*100mm (W*H*D)3.Mechanical Specification
4.Block Diagram
5.Derating Curve
6.Static Characteristics
7.Please Note
1. All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
5. Dual phase operation: derating of 20% is required.
-
If you have any enquiry about quotation or cooperation, please feel free to email us at maggie-liu@yqmingwei.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.